02T MD90FF18 1106FE 3306 1N6523U 3210 1210UFD 1N6517LL 1110UFE M100SG 1202C Z10FF5 K50S 3202 1410F 1202FB 1306 1N6531 FP200S 1N6517U Z20FF5LL 3506F LTI202P LTI206UFN 1110A LTI1410UF 1N5552 1106UFB
Nome do ítem | Fabricante | Aplicativo |
---|---|---|
X10SG | VMI | 1000 V rectifier 1.5 A forward current, 3000 ns recovery time |
LTI202TN | VMI | 200 V negative center tap 20-25 A forward current, 3000 ns recovery time |
LTI1402T | VMI | 200 V single phase bridge 20-25 A forward current, 3000 ns recovery time |
MD90FF18 | VMI | 1800 V rectifier, 0.5A forward current, 30ns-50ns recovery time |
1106FE | VMI | 600 V single phase bridge 1.4-1.5 A forward current, 150 ns recovery time |
3306 | VMI | 600 V three phase bridge 9-10 A forward current, 3000 ns recovery time |
1N6523U | VMI | 3000 V rectifier 0.15-0.5 A forward current, 70 ns recovery time |
3210 | VMI | 1000 V three phase bridge 4-5 A forward current, 3000 ns recovery time |
1210UFD | VMI | 1000 V single phase bridge 3.0 A forward current, 70 ns recovery time |
1N6517LL | VMI | 5000 V rectifier 1.5-3.5 A forward current, 70 ns recovery time |
1110UFE | VMI | 1000 V single phase bridge 1.4-1.5 A forward current, 70 ns recovery time |
M100SG | VMI | 10000 V rectifier 10-100 mA forward current, 3000 ns recovery time |
1202C | VMI | 200 V single phase bridge 3.0 A forward current, 3000 ns recovery time |
Z10FF5 | VMI | 1000 V rectifier 0.5-1 A forward current, 50 ns recovery time |
K50S | VMI | 5000 V rectifier 1.5-3 A forward current, 3000 ns recovery time |
3202 | VMI | 200 V three phase bridge 4-5 A forward current, 3000 ns recovery time |
1410F | VMI | 1000 V single phase bridge 12 A forward current, 150 ns recovery time |
1202FB | VMI | 200 V single phase bridge 3.0 A forward current, 150 ns recovery time |
1306 | VMI | 600 V single phase bridge 4.5-5 A forward current, 3000 ns recovery time |
1N6531 | VMI | 3000 V rectifier 25-250 mA forward current,70 ns recovery time |
FP200S | VMI | 20000 V rectifier stack 2.2 A forward current, 3000 ns recovery time |
1N6517U | VMI | 5000 V rectifier 2-5 A forward current, 70 ns recovery time |
Z20FF5LL | VMI | 2000 V rectifier 0.8-2.0 A forward current, 50 ns recovery time |
3506F | VMI | 600 V three phase bridge 40-60 A forward current,150 ns recovery time |
LTI202P | VMI | 200 V positive center tap 20-25 A forward current, 3000 ns recovery time |
LTI206UFN | VMI | 600 V negative center tap 20-25 A forward current, 70 ns recovery time |
1110A | VMI | 1000 V single phase bridge 1.4-1.5 A forward current, 3000 ns recovery time |
LTI1410UF | VMI | 1000 V single phase bridge 20-25 A forward current, 70 ns recovery time |
1N5552 | VMI | 600 V rectifier 5.0 A forward current, 2000 ns recovery time |
1106UFB | VMI | 600 V single phase bridge 1.4-1.5 A forward current, 70 ns recovery time |